{"id":2296,"date":"2026-06-11T06:16:00","date_gmt":"2026-06-11T06:16:00","guid":{"rendered":"https:\/\/www.hongtengdaparts.com\/?post_type=product&#038;p=2296"},"modified":"2026-06-11T06:16:00","modified_gmt":"2026-06-11T06:16:00","slug":"hitachi-4353686-capteur-de-pression","status":"publish","type":"product","link":"https:\/\/www.hongtengdaparts.com\/fr\/product\/hitachi-4353686-pressure-sensor\/","title":{"rendered":"Capteur de pression Hitachi 4353686 \u2013 Pour vanne de contr\u00f4le principale EX200-5 \/ EX300-5 (13,2 mm, 2 broches)"},"content":{"rendered":"<p><strong>Vid\u00e9o du produit<\/strong><\/p>\n<div style=\"width: 480px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-2296-1\" width=\"480\" height=\"854\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-.mp4?_=1\" \/><a href=\"https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-.mp4\">https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-.mp4<\/a><\/video><\/div>\n<div style=\"width: 480px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-2296-2\" width=\"480\" height=\"854\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-4353686.mp4?_=2\" \/><a href=\"https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-4353686.mp4\">https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Hitachi-Main-Control-Valve-Pressure-Sensor-4353686.mp4<\/a><\/video><\/div>\n<h3><span class=\"\">1. Le \u201c Calibrage Invisible \u201d \u2013 Pourquoi Deux Capteurs Identiques Peuvent Afficher des Valeurs Diff\u00e9rentes<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Vous poss\u00e9dez deux machines EX200-5. Les deux utilisent le m\u00eame capteur 4353686 sur la vanne de commande principale. Vous \u00e9changez les capteurs entre elles. Soudain, une machine r\u00e9agit diff\u00e9remment. Pourquoi ?<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Parce que chaque capteur pr\u00e9sente\u00a0<\/span><strong><span class=\"\">une l\u00e9g\u00e8re variation individuelle<\/span><\/strong><span class=\"\"> dans sa courbe tension-pression. Le calculateur ECU apprend (s\u2019adapte) au capteur qu\u2019il d\u00e9tecte au fil du temps. Lorsque vous \u00e9changez un capteur usag\u00e9 provenant d\u2019une autre machine, l\u2019ECU peut ne pas s\u2019adapter imm\u00e9diatement \u2013 ce qui entra\u00eene un comportement hydraulique \u00e9trange pendant les premi\u00e8res heures.<\/span><\/p>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Situation<\/span><\/th>\n<th><span class=\"\">R\u00e9sultat<\/span><\/th>\n<th><span class=\"\">Solution<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">Remplacer par un\u00a0<\/span><strong><span class=\"\">neuf<\/span><\/strong><span class=\"\">\u00a04353686<\/span><\/td>\n<td><span class=\"\">L\u2019ECU s\u2019adapte en 10 cycles<\/span><\/td>\n<td><span class=\"\">Aucun probl\u00e8me<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">\u00c9changer le capteur d\u2019une autre machine (m\u00eame num\u00e9ro de pi\u00e8ce)<\/span><\/td>\n<td><span class=\"\">Incompatibilit\u00e9 possible \u2013 r\u00e9ponse saccad\u00e9e ou lente pendant 1 \u00e0 2 heures<\/span><\/td>\n<td><span class=\"\">Continuer \u00e0 utiliser ; l\u2019adaptation se produira<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Remplacer par un\u00a0<\/span><strong><span class=\"\">capteur<\/span><\/strong><span class=\"\">\u00a0non\u2011d\u2019origine<\/span><\/td>\n<td><span class=\"\">L\u2019ECU peut ne jamais s\u2019adapter correctement \u2013 performances m\u00e9diocres permanentes<\/span><\/td>\n<td><span class=\"\">Uniquement capteur Hitachi 4353686 d\u2019origine<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Nos capteurs sont calibr\u00e9s en usine selon les sp\u00e9cifications Hitachi (pr\u00e9cision \u00b11%).<\/span><\/strong><span class=\"\">\u00a0Les copies non d\u2019origine pr\u00e9sentent souvent une pr\u00e9cision de \u00b15% ou pire \u2013 l\u2019ECU ne peut pas compenser compl\u00e8tement.<\/span><\/p>\n<h3><span class=\"\">2. Trois Modes de D\u00e9faillance Propres aux Capteurs de Vanne de Commande Principale<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Contrairement aux capteurs de pression sur les pompes ou les filtres, le 4353686 est install\u00e9 directement sur la vanne de commande principale \u2013 expos\u00e9 \u00e0\u00a0<\/span><strong><span class=\"\">des pics de pression haute fr\u00e9quence<\/span><\/strong><span class=\"\"> (jusqu\u2019\u00e0 500 Hz) provenant des d\u00e9placements de tiroirs. Cela entra\u00eene des sch\u00e9mas de d\u00e9faillance que vous ne rencontrerez pas ailleurs.<\/span><\/p>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Mode de d\u00e9faillance<\/span><\/th>\n<th><span class=\"\">Sympt\u00f4me<\/span><\/th>\n<th><span class=\"\">Cause Racine<\/span><\/th>\n<th><span class=\"\">M\u00e9thode de d\u00e9tection<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong><span class=\"\">D\u00e9collement de la jauge de contrainte<\/span><\/strong><\/td>\n<td><span class=\"\">La lecture de pression varie brusquement lorsque la machine heurte une roche<\/span><\/td>\n<td><span class=\"\">L\u2019adh\u00e9sif maintenant la jauge c\u00e8de sous l\u2019effet des vibrations<\/span><\/td>\n<td><span class=\"\">Tapotez l\u00e9g\u00e8rement le corps du capteur avec le manche d\u2019un tournevis \u2013 la sortie ne doit pas changer. Si c\u2019est le cas, la jauge est d\u00e9coll\u00e9e.<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">P\u00e9n\u00e9tration d\u2019huile interne<\/span><\/strong><\/td>\n<td><span class=\"\">La lecture d\u00e9rive lentement sur des heures (la pression semble augmenter lorsque la machine est \u00e9teinte)<\/span><\/td>\n<td><span class=\"\">Microfissure dans l\u2019\u00e9l\u00e9ment de d\u00e9tection en c\u00e9ramique<\/span><\/td>\n<td><span class=\"\">Laissez la machine \u00e9teinte toute une nuit. V\u00e9rifiez la tension le matin : elle doit \u00eatre identique \u00e0 celle de la veille. Si elle a augment\u00e9, le capteur aspire de l\u2019huile.<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Usure des broches du connecteur<\/span><\/strong><\/td>\n<td><span class=\"\">Code d\u2019erreur \u201c capteur de pression \u201d intermittent, surtout par temps froid<\/span><\/td>\n<td><span class=\"\">Micro-mouvement entre la broche et le connecteur d\u00fb aux vibrations<\/span><\/td>\n<td><span class=\"\">Agitez le connecteur tout en surveillant la tension \u2013 si elle change, les broches sont us\u00e9es. Remplacez \u00e0 la fois le capteur et le faisceau de raccordement.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Ces d\u00e9fauts ne sont pas d\u00e9tectables par un simple test de r\u00e9sistance.<\/span><\/strong><span class=\"\">\u00a0Vous devez observer le capteur dans des conditions de fonctionnement.<\/span><\/p>\n<h3><span class=\"\">3. Le \u201c Test de Tapotement \u201d \u2013 Diagnostic Rapide sur le Terrain Sans Multim\u00e8tre<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Vous pouvez diagnostiquer un 4353686 d\u00e9faillant en utilisant uniquement vos oreilles et une petite cl\u00e9.<\/span><\/p>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">\u00c9tape<\/span><\/th>\n<th><span class=\"\">Action<\/span><\/th>\n<th><span class=\"\">Capteur en bon \u00e9tat<\/span><\/th>\n<th><span class=\"\">Capteur d\u00e9fectueux<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">1<\/span><\/td>\n<td><span class=\"\">D\u00e9marrez le moteur, laissez-le au ralenti.<\/span><\/td>\n<td><span class=\"\">La machine tourne au ralenti en douceur.<\/span><\/td>\n<td><span class=\"\">\u2013<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">2<\/span><\/td>\n<td><span class=\"\">Tapotez l\u00e9g\u00e8rement le corps du capteur avec une cl\u00e9 de 10 mm (pas fort \u2013 juste un petit coup).<\/span><\/td>\n<td><span class=\"\">Aucun changement dans le bruit du moteur ou le comportement hydraulique.<\/span><\/td>\n<td><span class=\"\">Le r\u00e9gime moteur peut chuter ou augmenter ; vous pouvez entendre un clic provenant de la pompe principale (r\u00e9pondant \u00e0 un faux signal de pression).<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">3<\/span><\/td>\n<td><span class=\"\">Si aucun changement, tapotez un peu plus fort.<\/span><\/td>\n<td><span class=\"\">Toujours aucun changement.<\/span><\/td>\n<td><span class=\"\">Identique \u00e0 ce qui pr\u00e9c\u00e8de.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Pourquoi cela fonctionne :<\/span><\/strong><span class=\"\">\u00a0La sortie du 4353686 influence directement le contr\u00f4le de d\u00e9bit n\u00e9gatif de la pompe. Une jauge de contrainte d\u00e9coll\u00e9e convertira le tapotement m\u00e9canique en un faux pic de pression, provoquant une modification momentan\u00e9e du d\u00e9bit de la pompe.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Si la machine r\u00e9agit au tapotement \u2013 remplacez le capteur imm\u00e9diatement.<\/span><\/strong><\/p>\n<h3><span class=\"\">4. Cas R\u00e9el \u2013 Le \u201c Fant\u00f4me dans la Machine \u201d Qui a Pris Deux Ans \u00e0 R\u00e9soudre<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Une entreprise de construction au Chili poss\u00e9dait une EX300-5 qui perdait al\u00e9atoirement de la puissance en creusant. Le moteur calait pendant 2 \u00e0 3 secondes, puis reprenait. Cela se produisait une fois toutes les deux semaines \u2013 impossible \u00e0 reproduire pour un technicien.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Ils ont remplac\u00e9 les filtres \u00e0 carburant, les injecteurs, le contr\u00f4leur de pompe principale, et m\u00eame le calculateur moteur \u2013 plus de $6 000 en pi\u00e8ces sur deux ans. Le probl\u00e8me persistait.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Un sp\u00e9cialiste Hitachi de passage a effectu\u00e9 le \u201c test de tapotement \u201d sur le 4353686. Un seul tapotement. Le moteur a cal\u00e9. Ils ont remplac\u00e9 le capteur (moins de $100). Le probl\u00e8me n\u2019est jamais revenu.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">La jauge de contrainte du capteur pr\u00e9sentait une microfissure qui ne s\u2019ouvrait que sous une fr\u00e9quence de vibration sp\u00e9cifique \u2013 survenant al\u00e9atoirement lors du creusement. Aucun test statique n\u2019aurait pu la d\u00e9tecter.<\/span><\/strong><\/p>\n<h3><span class=\"\">5. Analyse Approfondie de l\u2019Installation \u2013 Le M\u00e9canisme d\u2019\u00c9tanch\u00e9it\u00e9 du Filetage de 13,2 mm<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Le 4353686 utilise un\u00a0<\/span><strong><span class=\"\">filetage M13,2 x 1,5<\/span><\/strong><span class=\"\"> avec un joint torique qui assure l\u2019\u00e9tanch\u00e9it\u00e9 dans un lamage. De nombreux m\u00e9caniciens serrent excessivement car ils s\u2019attendent \u00e0 une \u00e9tanch\u00e9it\u00e9 conique standard. Voici la proc\u00e9dure correcte :<\/span><\/p>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">\u00c9tape<\/span><\/th>\n<th><span class=\"\">Action<\/span><\/th>\n<th><span class=\"\">Couple \/ Sp\u00e9cification<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">1<\/span><\/td>\n<td><span class=\"\">Nettoyez le lamage avec une petite brosse (taille brosse \u00e0 dents)<\/span><\/td>\n<td><span class=\"\">Retirez tout r\u00e9sidu de produit d\u2019\u00e9tanch\u00e9it\u00e9 ancien<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">2<\/span><\/td>\n<td><span class=\"\">Inspecter le fond du lamage \u2013 rechercher des rayures ou des piq\u00fbres<\/span><\/td>\n<td><span class=\"\">En cas d\u2019endommagement, le joint torique risque de ne pas assurer l\u2019\u00e9tanch\u00e9it\u00e9. Utiliser un produit d\u2019\u00e9tanch\u00e9it\u00e9 liquide avec parcimonie (Loctite 567) en dernier recours.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">3<\/span><\/td>\n<td><span class=\"\">Lubrifier le nouveau joint torique avec de l\u2019huile hydraulique propre<\/span><\/td>\n<td><span class=\"\">Ne pas utiliser de graisse \u2013 elle pourrait obstruer l\u2019orifice de pression<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">4<\/span><\/td>\n<td><span class=\"\">Visser \u00e0 la main jusqu\u2019\u00e0 ce que ce soit serr\u00e9<\/span><\/td>\n<td><span class=\"\">3 \u00e0 4 tours complets \u00e0 la main<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">5<\/span><\/td>\n<td><span class=\"\">Serrer avec une cl\u00e9<\/span><\/td>\n<td><strong><span class=\"\">12\u201315 Nm<\/span><\/strong><span class=\"\">\u00a0(pas 20 Nm comme pour d\u2019autres capteurs)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">6<\/span><\/td>\n<td><span class=\"\">Faire fonctionner la machine et v\u00e9rifier l\u2019absence de fuites<\/span><\/td>\n<td><span class=\"\">En cas de fuite, serrer d\u20191\/8 de tour suppl\u00e9mentaire \u2013 ne pas d\u00e9passer 18 Nm<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Pourquoi un couple si faible ?<\/span><\/strong><span class=\"\">\u00a0Le corps de vanne en aluminium est tendre. Un serrage excessif ab\u00eeme les filets ou fissure le bossage \u2013 une r\u00e9paration \u00e0 $3 000.<\/span><\/p>\n<h3><span class=\"\">6. R\u00e9f\u00e9rences crois\u00e9es du capteur \u2013 Quels autres mod\u00e8les conviennent (et lesquels ne conviennent pas)<\/span><\/h3>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Num\u00e9ro de pi\u00e8ce<\/span><\/th>\n<th><span class=\"\">Interchangeable ?<\/span><\/th>\n<th><span class=\"\">Notes<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">4353686<\/span><\/td>\n<td><span class=\"\">\u2013<\/span><\/td>\n<td><span class=\"\">Original pour vanne principale EX200-5\/300-5<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">4333040<\/span><\/td>\n<td><span class=\"\">\u274c Non<\/span><\/td>\n<td><span class=\"\">Filetage diff\u00e9rent (13 mm) et temps de r\u00e9ponse diff\u00e9rent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">4332040<\/span><\/td>\n<td><span class=\"\">\u274c Non<\/span><\/td>\n<td><span class=\"\">3 broches, application diff\u00e9rente<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">4378790<\/span><\/td>\n<td><span class=\"\">\u274c Non<\/span><\/td>\n<td><span class=\"\">Utilis\u00e9 sur la s\u00e9rie ZAX (calibration diff\u00e9rente)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Pi\u00e8ce de rechange \u201c compatible 4353686 \u201d<\/span><\/td>\n<td><span class=\"\">\u26a0\ufe0f Risqu\u00e9<\/span><\/td>\n<td><span class=\"\">Peut avoir un pas de vis incorrect ou un temps de r\u00e9ponse plus lent. Tester minutieusement avant d\u2019accepter.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Nous fournissons uniquement le Hitachi 4353686 d\u2019origine<\/span><\/strong><span class=\"\">\u00a0\u2013 pas de \u201c compatible \u201d ou \u201c remplacement pour \u201d. La calibration est importante.<\/span><\/p>\n<h3><span class=\"\">7. Quand remplacer de mani\u00e8re pr\u00e9ventive \u2013 Une r\u00e8gle simple bas\u00e9e sur les heures<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Le 4353686 n\u2019a pas d\u2019intervalle de remplacement officiel. Bas\u00e9 sur les donn\u00e9es terrain de plus de 500 machines EX200-5\/300-5 :<\/span><\/p>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Heures machine<\/span><\/th>\n<th><span class=\"\">Action recommand\u00e9e<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">0\u20135 000 heures<\/span><\/td>\n<td><span class=\"\">Remplacer uniquement en cas de sympt\u00f4mes<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">5 000\u20138 000 heures<\/span><\/td>\n<td><span class=\"\">Tester annuellement (test de tapotement + v\u00e9rification de tension)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">8 000\u201310 000 heures<\/span><\/td>\n<td><span class=\"\">Envisager un remplacement pr\u00e9ventif \u2013 le taux de d\u00e9faillance augmente<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">10 000+ heures<\/span><\/td>\n<td><span class=\"\">Remplacer de mani\u00e8re pr\u00e9ventive. L\u2019adh\u00e9sif de la jauge de contrainte s\u2019est probablement d\u00e9grad\u00e9.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Co\u00fbt du remplacement pr\u00e9ventif :<\/span><\/strong><span class=\"\">\u00a0&lt; $100 + 15 minutes.<\/span><br \/>\n<span class=\"\">**Co\u00fbt d\u2019une d\u00e9faillance (temps d\u2019arr\u00eat, erreur de diagnostic, perte de production) :** Souvent $1 000\u2013$5 000.<\/span><\/p>\n<h3><span class=\"\">8. Contenu du produit \u2013 Kit d\u2019origine<\/span><\/h3>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Article<\/span><\/th>\n<th><span class=\"\">Inclus<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">Capteur de pression 4353686<\/span><\/td>\n<td><span class=\"\">\u2705 (Fabriqu\u00e9 au Japon, marque Hitachi)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Joint torique (pour lamage)<\/span><\/td>\n<td><span class=\"\">\u2705 (Pr\u00e9-install\u00e9, NBR70)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Capuchon de protection<\/span><\/td>\n<td><span class=\"\">\u2705<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Bo\u00eete en carton avec \u00e9tiquette<\/span><\/td>\n<td><span class=\"\">\u2705<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">(Optionnel) Faisceau \u00e0 2 broches<\/span><\/td>\n<td><span class=\"\">Sur demande (suppl\u00e9ment, pour connecteurs corrod\u00e9s)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Non inclus :<\/span><\/strong><span class=\"\">\u00a0Produit d\u2019\u00e9tanch\u00e9it\u00e9 pour filets, cl\u00e9 dynamom\u00e9trique, graisse di\u00e9lectrique.<\/span><\/p>\n<h3><span class=\"\">9. Commande et livraison<\/span><\/h3>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Article<\/span><\/th>\n<th><span class=\"\">D\u00e9tail<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span class=\"\">MOQ<\/span><\/td>\n<td><span class=\"\">1 pi\u00e8ce<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">D\u00e9lai de production<\/span><\/td>\n<td><span class=\"\">6 \u00e0 8 jours ouvr\u00e9s<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Emballage<\/span><\/td>\n<td><span class=\"\">Bo\u00eete en carton dans enveloppe rembourr\u00e9e<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Paiement<\/span><\/td>\n<td><span class=\"\">T\/T, XTransfer, PayPal, Western Union<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Capacit\u00e9 d\u2019approvisionnement<\/span><\/td>\n<td><span class=\"\">300 pi\u00e8ces\/mois<\/span><\/td>\n<\/tr>\n<tr>\n<td><span class=\"\">Garantie<\/span><\/td>\n<td><span class=\"\">6 mois (d\u00e9fauts de fabrication \u2013 jauge de contrainte, joint, connecteur)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3><span class=\"\">10. Avant de commander \u2013 Une photo fait gagner des heures<\/span><\/h3>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Veuillez envoyer :<\/span><\/p>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Photo de votre ancien capteur<\/span><\/strong><span class=\"\">\u00a0(montrant la taille du six pans et la forme g\u00e9n\u00e9rale)<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Num\u00e9ro de s\u00e9rie de la machine<\/span><\/strong><span class=\"\">\u00a0(EX200-5-xxxxx ou EX300-5-xxxxx)<\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Nous confirmerons la compatibilit\u00e9 sous\u00a0<\/span><strong><span class=\"\">24 heures<\/span><\/strong><span class=\"\">.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Le 4353686 est une petite pi\u00e8ce avec une grande responsabilit\u00e9. Remplacez-la par une pi\u00e8ce d\u2019origine \u2013 et faites confiance au signal.<\/span><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td><b>Mod\u00e8le applicable<\/b><\/td>\n<td>Hitachi EX200-5, EX300-5<\/td>\n<\/tr>\n<tr>\n<td><b>Num\u00e9ro de pi\u00e8ce<\/b><\/td>\n<td>4353686<\/td>\n<\/tr>\n<tr>\n<td><b>Nom<\/b><\/td>\n<td>Capteur de pression<\/td>\n<\/tr>\n<tr>\n<td><b>Item Package Quantity<\/b><\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td><b>Piles incluses ?<\/b><\/td>\n<td>Non<\/td>\n<\/tr>\n<tr>\n<td><b>Manufacturer<\/b><\/td>\n<td>Japon<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Remarque : Les informations d\u2019application fournies sont \u00e0 titre indicatif uniquement. Veuillez confirmer le num\u00e9ro de pi\u00e8ce et le comparer avec l\u2019ancien composant avant d\u2019acheter. Pour toute question, n\u2019h\u00e9sitez pas \u00e0\u00a0<a href=\"https:\/\/www.hongtengdaparts.com\/fr\/nous-contacter\/\">nous contacter<\/a>.<\/strong><br \/>\n<strong>Il est judicieux de choisir un produit offrant des performances stables, une fiabilit\u00e9 \u00e9lev\u00e9e, une installation facile et une r\u00e9ponse rapide.<\/strong><\/p>","protected":false},"featured_media":2302,"template":"","meta":[],"product_brand":[],"product_cat":[57],"product_tag":[],"class_list":["post-2296","product","type-product","status-publish","has-post-thumbnail","product_cat-excavator-sensor","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/product\/2296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/media\/2302"}],"wp:attachment":[{"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/media?parent=2296"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2296"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}