{"id":4964,"date":"2026-11-19T10:24:00","date_gmt":"2026-11-19T10:24:00","guid":{"rendered":"https:\/\/www.hongtengdaparts.com\/kawasaki-kpm-sy480-sy550-main-pump-fitment-why-model-names-are-not-enough\/"},"modified":"2026-11-13T02:42:22","modified_gmt":"2026-11-13T02:42:22","slug":"kawasaki-kpm-sy480-sy550-main-pump-fitment-why-model-names-are-not-enough","status":"publish","type":"post","link":"https:\/\/www.hongtengdaparts.com\/vi\/kawasaki-kpm-sy480-sy550-main-pump-fitment-why-model-names-are-not-enough\/","title":{"rendered":"Kawasaki KPM SY480 \/ SY550 L\u1eafp \u0111\u1eb7t b\u01a1m ch\u00ednh: V\u00ec sao t\u00ean model l\u00e0 kh\u00f4ng \u0111\u1ee7"},"content":{"rendered":"<figure><img src=\"https:\/\/www.hongtengdaparts.com\/wp-content\/uploads\/2026\/06\/Kawasaki-KPM-SY480-SY550-Main-Hydraulic-Pump-2.jpeg\" alt=\"\u5ddd\u5d0eKPM SY480 \/ SY550\u4e3b\u6cf5\u6316\u6398\u673a\u96f6\u4ef6\u8bc6\u522b\u4e0e\u66f4\u6362\u9a8c\u8bc1\" loading=\"eager\" decoding=\"async\"><figcaption>Catalog image associated with Kawasaki KPM SY480 \/ SY550 Main Hydraulic Pump \u2013 Genuine New (603555586). Exact serial fitment and supplied scope require written confirmation.<\/figcaption><\/figure>\n<p>Kawasaki KPM SY480 \/ SY550 Main Pump is presented in the Hongtengda catalog as an excavator-parts inquiry reference. This guide explains how a workshop, fleet owner, or distributor can diagnose the surrounding system, define the part correctly, compare a quotation, and commission the machine without turning a catalog association into an unsupported fitment promise. A pump can be blamed for a regulator, suction, oil, cooling, relief, sensor, wiring, or engine-speed problem. The practical task is therefore to build an evidence chain: identify the machine, document the old unit, test the system, inspect every interface, control contamination, and record the result. The product title and photograph are useful starting points. They do not by themselves prove interchangeability, internal specification, software, calibration, pressure setting, material, stock, delivery, warranty, or suitability for a particular serial number.<\/p>\n<h2>X\u00e1c \u0111\u1ecbnh ch\u00ednh x\u00e1c c\u1ea5u h\u00ecnh \u0111ang \u0111\u01b0\u1ee3c mua<\/h2>\n<p>The component works within the excavator hydraulic power circuit and its general role is to convert engine input into controlled hydraulic flow for the machine functions. The article follows the job from symptom capture through identification, controlled testing, purchasing, installation, and staged acceptance. Typical complaints include slow combined movements, engine loading, unstable pump command, abnormal noise, heat, leakage, and poor pressure recovery. Those observations are valuable only when the operating condition is recorded. Note oil and coolant temperature, engine speed, selected work mode, attachment load, travel direction, upper-structure position, active codes, and whether the problem is constant or intermittent. Use the exact machine service information for safety, test connections, limits, fluids, tightening procedures, software steps, and acceptance criteria. General industry sources in this article explain methods; they do not establish model-specific values. For the quoted main hydraulic pump, mark this checkpoint as confirmed, unresolved, or not applicable before approval.<\/p>\n<h2>L\u1eadp b\u1ed9 nh\u1eadn di\u1ec7n s\u1ed1 s\u00ea-ri v\u00e0 giao di\u1ec7n<\/h2>\n<p>Begin with the full machine identification number and a readable record of the removed part. For Kawasaki KPM SY480 \/ SY550 Main Pump, collect pump tag, shaft and flange geometry, port map, regulator or solenoid arrangement, pressure and flow records, case-drain trend, oil condition, and machine serial data. Photograph the installed orientation before disconnecting anything, then add a simple sketch that gives every hose, connector, bracket, and adjacent obstruction a unique label. Do not collapse different evidence fields into one model name. A supplier needs to know which observation came from the machine plate, which came from the old component, and which came from an online or paper catalog. If two identifiers conflict, preserve the conflict and resolve it before shipment. The following table is designed to travel with the RFQ, quotation, receiving inspection, and workshop job card.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u8bc1\u636e\u7ec4<\/th>\n<th>What the RFQ or job file should contain<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u673a\u5668\u8eab\u4efd<\/td>\n<td>Record full machine model and serial\/PIN before relying on a model family name.<\/td>\n<\/tr>\n<tr>\n<td>Old-unit identity<\/td>\n<td>Photograph every tag, casting mark, connector, port, flange, and orientation clue.<\/td>\n<\/tr>\n<tr>\n<td>Interface evidence<\/td>\n<td>pump tag, shaft and flange geometry, port map, regulator or solenoid arrangement, pressure and flow records, case-drain trend, oil condition, and machine serial data<\/td>\n<\/tr>\n<tr>\n<td>\u6545\u969c\u8bc1\u636e<\/td>\n<td>pressure, flow, command, case drain, oil temperature, engine speed, and contamination evidence<\/td>\n<\/tr>\n<tr>\n<td>\u5546\u52a1\u8303\u56f4<\/td>\n<td>Confirm condition, included hardware, preservation, test evidence, packing, lead time, and warranty in writing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ki\u1ec3m tra tr\u01b0\u1edbc khi coi t\u01b0\u01a1ng th\u00edch l\u00e0 nguy\u00ean nh\u00e2n l\u1ed7i<\/h2>\n<p>Create a baseline while the machine is still complete whenever safe access is possible. Record pressure, flow, command, case drain, oil temperature, engine speed, and contamination evidence. Compare repeatable operating points rather than isolated readings. A value taken with a cold machine, unknown engine speed, or different command cannot be compared reliably with a hot loaded test. Separate cause, consequence, and collateral damage. A weak actuator may change pump sound; a restricted return may create heat; a damaged harness may create a control response that resembles hydraulic wear. The objective is not to collect the largest number of measurements. It is to select tests that can disprove competing causes. Stop testing when stored hydraulic energy, unstable support, rotating parts, hot surfaces, fuel pressure, or uncontrolled movement cannot be managed. Depressurization, isolation, lifting, blocking, cleanliness, and personal protection must follow the machine and component instructions. The Kawasaki KPM SY480 \/ SY550 Main Pump job card should show who completed this check, under what operating condition, and with which source.<\/p>\n<h2>Gi\u1ea3i quy\u1ebft c\u00e1c th\u1ebb v\u00e0 giao di\u1ec7n xung \u0111\u1ed9t<\/h2>\n<p>Inspect shaft condition, mounting pilot, port threads, regulator hardware, leakage paths, rotating-group evidence, contamination, and coupling condition. Treat contamination and damaged interfaces as system evidence, not merely as defects to wipe away. Photograph the condition before cleaning, sample fluids through a controlled method where required, and keep removed filters or magnetic debris linked to the job record. A replacement decision should explain why the observed failure could create the complaint and why plausible alternatives were rejected. If the evidence does not connect the component to the symptom, continue diagnosis. This discipline protects both the buyer and supplier from an expensive but inconclusive parts swap. When a removed unit is sent for evaluation, preserve ports and connectors immediately. Identify whether the report concerns the complete assembly, one subcomponent, or only the visible exterior. A clean exterior is not proof of acceptable internal condition, and an internal defect is not proof that every interface matches the offered replacement. When comparing offers for Kawasaki KPM SY480 \/ SY550 Main Pump, ask each supplier to respond to this same evidence point in writing.<\/p>\n<h2>Quy\u1ebft \u0111\u1ecbnh xem c\u1ea7n s\u1eeda ch\u1eefa hay c\u1ea7n m\u1ed9t c\u1ee5m kh\u00e1c<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u51b3\u7b56<\/th>\n<th>Evidence pattern<\/th>\n<th>Required next action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Continue diagnosis<\/td>\n<td>Identity is uncertain or system evidence points outside the main hydraulic pump.<\/td>\n<td>Complete controlled tests and compare both sides of the circuit.<\/td>\n<\/tr>\n<tr>\n<td>Repair or rebuild<\/td>\n<td>Interfaces are correct and recoverable wear is documented.<\/td>\n<td>Agree on parts scope, measurements, cleanliness, test method, and acceptance record.<\/td>\n<\/tr>\n<tr>\n<td>Replace assembly<\/td>\n<td>Structural or precision surfaces are unsuitable, scope is uncertain, or downtime favors a complete unit.<\/td>\n<td>Match the complete interface set and obtain written condition and test evidence.<\/td>\n<\/tr>\n<tr>\n<td>Stop and escalate<\/td>\n<td>Cracking, unsafe stored energy, severe contamination, uncontrolled movement, or missing service information is present.<\/td>\n<td>Use the machine manual and a qualified repair process before continuing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ma tr\u1eadn so s\u00e1nh v\u00e0 ch\u1ea5p nh\u1eadn nh\u00e0 cung c\u1ea5p<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0110i\u1ec3m ki\u1ec3m so\u00e1t<\/th>\n<th>B\u1eb1ng ch\u1ee9ng t\u1eeb nh\u00e0 cung c\u1ea5p ho\u1eb7c x\u01b0\u1edfng<\/th>\n<th>C\u01a1 s\u1edf ch\u1ea5p nh\u1eadn<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u8eab\u4efd<\/td>\n<td>Nh\u00e0 cung c\u1ea5p nh\u1eafc l\u1ea1i b\u1eb1ng v\u0103n b\u1ea3n s\u1ed1 s\u00ea-ri m\u00e1y, m\u00e3 tham chi\u1ebfu c\u1ee5m c\u0169 v\u00e0 b\u1eb1ng ch\u1ee9ng giao di\u1ec7n quy\u1ebft \u0111\u1ecbnh.<\/td>\n<td>Kh\u00f4ng c\u00f3 xung \u0111\u1ed9t th\u1ebb ho\u1eb7c giao di\u1ec7n ch\u01b0a \u0111\u01b0\u1ee3c gi\u1ea3i quy\u1ebft.<\/td>\n<\/tr>\n<tr>\n<td>T\u00ecnh tr\u1ea1ng v\u00e0 ph\u1ea1m vi<\/td>\n<td>B\u00e1o gi\u00e1 n\u00eau r\u00f5 t\u00ecnh tr\u1ea1ng m\u1edbi, t\u00e1i s\u1ea3n xu\u1ea5t ho\u1eb7c \u0111\u00e3 qua s\u1eed d\u1ee5ng c\u00f9ng m\u1ecdi h\u1ea1ng m\u1ee5c \u0111\u01b0\u1ee3c bao g\u1ed3m v\u00e0 lo\u1ea1i tr\u1eeb.<\/td>\n<td>Ph\u1ea1m vi kh\u1edbp v\u1edbi \u0111\u01a1n \u0111\u1eb7t h\u00e0ng v\u00e0 danh s\u00e1ch ki\u1ec3m tra nh\u1eadn h\u00e0ng.<\/td>\n<\/tr>\n<tr>\n<td>\u6d4b\u8bd5\u8bc1\u636e<\/td>\n<td>H\u1ed3 s\u01a1 ki\u1ec3m tra ho\u1eb7c th\u1eed nghi\u1ec7m \u00e1p d\u1ee5ng x\u00e1c \u0111\u1ecbnh \u0111\u01a1n v\u1ecb th\u1ef1c t\u1ebf \u0111\u01b0\u1ee3c cung c\u1ea5p v\u00e0 ranh gi\u1edbi th\u1eed nghi\u1ec7m.<\/td>\n<td>B\u1eb1ng ch\u1ee9ng c\u00f3 th\u1ec3 truy xu\u1ea5t ngu\u1ed3n g\u1ed1c v\u00e0 ph\u00f9 h\u1ee3p v\u1edbi lo\u1ea1i linh ki\u1ec7n.<\/td>\n<\/tr>\n<tr>\n<td>H\u1eadu c\u1ea7n v\u00e0 b\u1ea3o qu\u1ea3n<\/td>\n<td>\u0110\u00f3ng g\u00f3i, b\u1ea3o v\u1ec7 c\u1ed5ng k\u1ebft n\u1ed1i, l\u01b0u kho, c\u01a1 s\u1edf giao h\u00e0ng v\u00e0 b\u00e1o c\u00e1o h\u01b0 h\u1ecfng \u0111\u01b0\u1ee3c quy \u0111\u1ecbnh r\u00f5.<\/td>\n<td>\u0110\u01a1n v\u1ecb h\u00e0ng \u0111\u1ebfn \u0111\u01b0\u1ee3c b\u1ea3o v\u1ec7, nh\u1eadn di\u1ec7n \u0111\u01b0\u1ee3c v\u00e0 s\u1ea1ch s\u1ebd.<\/td>\n<\/tr>\n<tr>\n<td>Nghi\u1ec7m thu<\/td>\n<td>C\u00e1c quan s\u00e1t khi ch\u1ea1y th\u1eed nghi\u1ec7m thu v\u00e0 b\u1eb1ng ch\u1ee9ng tr\u01b0\u1edbc\/sau c\u00f3 th\u1ec3 so s\u00e1nh \u0111\u01b0\u1ee3c \u0111\u1ec1u \u0111\u01b0\u1ee3c l\u01b0u gi\u1eef.<\/td>\n<td>Kh\u00f4ng ghi nh\u1eadn r\u00f2 r\u1ec9, m\u00e3 l\u1ed7i, ti\u1ebfng \u1ed3n b\u1ea5t th\u01b0\u1eddng ho\u1eb7c sai l\u1ec7ch v\u1eadn h\u00e0nh ch\u01b0a \u0111\u01b0\u1ee3c gi\u1ea3i quy\u1ebft.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Repair economics must include machine downtime, removal and installation labor, supporting-system cleanup, calibration or programming, freight, and the consequence of a repeat failure. Compare quotations on the same scope. A low price for a bare unit is not equivalent to a tested assembly with the required controls, fittings, documentation, and preservation. For remanufactured parts, ask which wear items and precision surfaces were inspected, what was replaced, how cleanliness was controlled, and what test record accompanies the serialised unit. For a new unit, ask for traceable identity, storage condition, protective packaging, and the exact supplied configuration. Keep this result in the receiving and commissioning file for Kawasaki KPM SY480 \/ SY550 Main Pump so a later review can reproduce the decision.<\/p>\n<h2>Y\u00eau c\u1ea7u nh\u00e0 cung c\u1ea5p x\u00e1c nh\u1eadn t\u1eebng giao di\u1ec7n quy\u1ebft \u0111\u1ecbnh<\/h2>\n<p>A useful RFQ for Kawasaki KPM SY480 \/ SY550 Main Pump includes the machine serial, application, full old-unit identity, interface photographs, measured geometry, symptom history, test evidence, related repairs, contamination findings, required condition, included hardware, destination, and deadline. Ask the supplier to repeat the decisive identifiers and scope on the quotation rather than replying only with a price. The catalog page for Kawasaki KPM SY480 \/ SY550 Main Pump can be reviewed <a href=\"https:\/\/www.hongtengdaparts.com\/vi\/san-pham\/%e5%b7%9d%e5%b4%8e-kpm-sy480-sy550-%e4%b8%bb%e6%b6%b2%e5%8e%8b%e6%b3%b5\/\">here<\/a>. Use it as an inquiry anchor and send the evidence package before treating the listing as a fitment confirmation. For a broader buying process, review <a href=\"https:\/\/www.hongtengdaparts.com\/vi\/%e6%8c%96%e6%8e%98%e6%9c%ba%e4%b8%bb%e6%b3%b5%e8%b0%83%e8%8a%82%e5%99%a8%e8%af%8a%e6%96%ad%e8%b0%83%e6%95%b4\/\">this related excavator guide<\/a> \u4ee5\u53ca <a href=\"https:\/\/www.hongtengdaparts.com\/vi\/%e6%8c%96%e6%8e%98%e6%9c%ba%e6%b6%b2%e5%8e%8b%e6%b3%b5%e5%af%86%e5%b0%81%e5%a5%97%e4%bb%b6\/\">this supporting diagnostic article<\/a>. Commercial claims should be written. Confirm the actual unit condition, included accessories, test documentation, packing method, lead time, shipping terms, return conditions, and warranty basis for the quoted item.<\/p>\n<h2>Th\u1ef1c hi\u1ec7n so s\u00e1nh khi nh\u1eadn h\u00e0ng song song<\/h2>\n<p>Quarantine the shipment until identity and condition are checked. Compare the packing label, unit tag, photographs, ports, connectors, mounting pattern, dimensions, handedness, and accessories with the approved quotation. Look for impact, corrosion, missing plugs, displaced seals, loose hardware, and contamination. Keep the old and replacement units side by side in the same orientation. Use a written comparison sheet and mark each decisive interface as matched, unmatched, or unresolved. Do not modify a bracket, connector, port, shaft, housing, or calibrated control to make an uncertain part fit; return the question to the supplier with photographs and measurements. Store the part according to its preservation requirements. Keep protective caps in place until the connection is ready, and keep electronic connectors dry and protected from electrostatic and mechanical damage. A workshop evaluating Kawasaki KPM SY480 \/ SY550 Main Pump should resolve this point before modifying, installing, or returning the component.<\/p>\n<h2>B\u1ea3o v\u1ec7 c\u00e1c giao di\u1ec7n \u0111\u00e3 x\u00e1c minh trong qu\u00e1 tr\u00ecnh l\u1eafp \u0111\u1eb7t<\/h2>\n<p>Before installation, correct the cause identified during diagnosis. Clean or replace affected lines, coolers, tanks, filters, breathers, fittings, and related components to the scope required by the failure evidence and service information. Transfer only confirmed fittings or controls, and document every transferred item. Use clean caps and dedicated plugs. Clean surrounding areas before opening the system, inspect hoses internally where damage or contamination is plausible, and never use lint-producing material on precision hydraulic or fuel interfaces. Lubricants, assembly fluids, seals, fasteners, and tightening methods must come from the exact service information. Route hoses and harnesses using the pre-removal labels. Check bend radius, twist, clamp position, heat exposure, abrasion, connector locks, ground paths, and service access. A correctly identified component can still fail when installation creates a new restriction, leak, electrical drop, or alignment error. For this Kawasaki KPM SY480 \/ SY550 Main Pump inquiry, store the finding with the machine serial, old-unit photographs, and test record.<\/p>\n<h2>X\u00e1c nh\u1eadn \u0111\u1ed9 v\u1eeba kh\u00edt trong v\u1eadn h\u00e0nh theo t\u1eebng giai \u0111o\u1ea1n<\/h2>\n<p>Prime, fill, bleed, program, or calibrate only as the applicable machine and component procedure requires. Begin with a static inspection, then a low-risk initial operation, then no-load function checks, then progressively higher demand. Stop at every stage to check leaks, noise, temperature, codes, fluid levels, and unexpected movement. Repeat the same baseline measurements used before removal: pressure, flow, command, case drain, oil temperature, engine speed, and contamination evidence . A successful result is an evidence-based change under comparable conditions. Record the date, technician, machine hours, ambient condition, instruments, test points, readings, and observations so another person can audit the decision. Retain the packaging, quotation, receiving photographs, old-part images, test results, fluid or filter evidence, programming record, and commissioning sheet. This dossier is essential if a fault returns or a warranty review is needed. For the quoted main hydraulic pump, mark this checkpoint as confirmed, unresolved, or not applicable before approval.<\/p>\n<h2>\u4e3b\u8981\u6280\u672f\u53c2\u8003\u548c\u58f0\u660e\u9650\u5236<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.boschrexroth.com\/en\/us\/c\/documentation-and-resources-mobile-hydraulics\/\" target=\"_blank\" rel=\"noopener\">www.boschrexroth.com \u6280\u672f\u6765\u6e90<\/a><\/li>\n<li><a href=\"https:\/\/www.donaldson.com\/en\/resources\/technical-articles\/minimizing-hydraulic-system-contamination\/\" target=\"_blank\" rel=\"noopener\">www.donaldson.com \u6280\u672f\u6765\u6e90<\/a><\/li>\n<li><a href=\"https:\/\/www.hse.gov.uk\/work-equipment-machinery\/maintenance.htm\" target=\"_blank\" rel=\"noopener\">www.hse.gov.uk \u6280\u672f\u6765\u6e90<\/a><\/li>\n<\/ul>\n<p>These sources support general service, diagnostic, safety, cleanliness, sealing, electrical, engine, or hydraulic principles as applicable. They do not confirm that Kawasaki KPM SY480 \/ SY550 Main Pump fits a particular machine serial, nor do they provide the serial-specific limits for this catalog item. Use <a href=\"https:\/\/www.hongtengdaparts.com\/vi\/lien-he-voi-chung-toi\/\">\u5b8f\u817e\u8fbe\u8054\u7cfb\u9875\u9762<\/a> \u53d1\u9001\u673a\u5668\u5e8f\u5217\u53f7\u3001\u65e7\u4ef6\u6807\u7b7e\u3001\u63a5\u53e3\u7167\u7247\u3001\u6d4b\u91cf\u503c\u3001\u6545\u969c\u8bc1\u636e\u3001\u6240\u9700\u72b6\u6001\u548c\u76ee\u7684\u5730\uff0c\u4ee5\u83b7\u53d6\u4e66\u9762\u6bd4\u8f83\u3002.<\/p>\n<h2>\u5e38\u89c1\u95ee\u9898<\/h2>\n<h3>Does the model name prove that Kawasaki KPM SY480 \/ SY550 Main Pump will fit?<\/h3>\n<p>No. Model-family wording is an inquiry clue. Serial breaks, regional builds, engine or hydraulic arrangements, software, connectors, ports, mounts, and previous repairs can change the required part. The Kawasaki KPM SY480 \/ SY550 Main Pump job card should show who completed this check, under what operating condition, and with which source.<\/p>\n<h3>\u5f53\u6545\u969c\u7801\u6216\u75c7\u72b6\u6307\u5411\u8be5\u90e8\u4ef6\u65f6\uff0c\u8f66\u95f4\u662f\u5426\u5e94\u66f4\u6362\u8be5\u96f6\u4ef6\uff1f<\/h3>\n<p>Not automatically. A pump can be blamed for a regulator, suction, oil, cooling, relief, sensor, wiring, or engine-speed problem. Verify the circuit or system and document the evidence before ordering. When comparing offers for Kawasaki KPM SY480 \/ SY550 Main Pump, ask each supplier to respond to this same evidence point in writing.<\/p>\n<h3>\u4e70\u65b9\u5728\u9996\u6b21\u8be2\u4ef7\u65f6\u5e94\u53d1\u9001\u4ec0\u4e48\uff1f<\/h3>\n<p>Send the complete machine serial, old-unit labels, installed and removed photographs, decisive dimensions and interfaces, pressure, flow, command, case drain, oil temperature, engine speed, and contamination evidence, required condition, destination, and timing. Keep this result in the receiving and commissioning file for Kawasaki KPM SY480 \/ SY550 Main Pump so a later review can reproduce the decision.<\/p>","protected":false},"excerpt":{"rendered":"<p>Technical guide to diagnose and source Kawasaki KPM SY480 \/ SY550 Main Pump using serial, interface, test, installation and commissioning evidence.<\/p>","protected":false},"author":1,"featured_media":2617,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4964","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/posts\/4964","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/comments?post=4964"}],"version-history":[{"count":1,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/posts\/4964\/revisions"}],"predecessor-version":[{"id":4965,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/posts\/4964\/revisions\/4965"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/media\/2617"}],"wp:attachment":[{"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/media?parent=4964"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/categories?post=4964"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hongtengdaparts.com\/vi\/wp-json\/wp\/v2\/tags?post=4964"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}