708-1S-00241 Fan Pump for Komatsu D65EX D85PX-15 Dozer, Pump Assembly

제품 설명:

부품: 708-1S-00241 hydraulic fan pump for Komatsu D61, D65 and D85 -15 series track-type tractors. Komatsu lists it under Hydraulics with the item name Pump Assembly.

역할: meters the oil that drives the cooling fan motor. The matching motor on these machines is 708-7S-00352.

공급 형태: 중국 제조 HTD 브랜드 신품 대체품입니다. 최소 주문 수량 1개, 목재 케이스 포장, 발송까지 5~8 영업일이 소요됩니다.

설명

Komatsu’s catalogue names this part Pump Assembly and files it in the same hydraulics group as the fan motors, and the trade applies it consistently to the cooling fan on the -15 generation dozers. Within Komatsu’s 708 numbering, the 1x series carries the pumps and the 7x series the motors, which is why 708-1S-00241 and 708-7S-00352 appear as a pair on the same machine.

적용 기종

Komatsu D61EX, D61PX, D65EX, D65PX, D65WX, D85EX, D85MS and D85PX of the -15 series. Komatsu publishes no displacement, pressure or flow figure for this number, so none is quoted here; if you are matching against a data sheet, the number on your housing and the machine serial prefix are the reliable references.

What this pump actually does on a dozer

A dozer’s cooling demand is unusual: long low-speed cycles with the converter loaded, enormous dust, and a fan that has to pull air through a radiator, an oil cooler and an aftercooler stacked behind one grille. The fan pump converts engine rotation into oil flow for the fan motor, and on this generation its output is governed by cooling demand rather than engine speed. When it wears, the fan stops reaching full speed exactly when the machine needs it most, which is at the end of a push cycle on a hot day.

Pump or motor: the test that decides the order

  • Clean the cores first and re-measure. On a dozer this resolves a large share of heat complaints with no parts at all.
  • Measure flow and pressure at the pump output with the oil hot. Short output points here.
  • Correct output with a fan that still lags and a heavy case drain at the motor points at the motor instead.
  • No command signal arriving is a third possibility, and a new pump will not fix it.

The full procedures are in our 유압 팬 펌프 진단 가이드 및 팬 모터 진단 가이드.

장착

Match shaft spline, pilot diameter, flange, port positions and the control orientation against the removed pump. Prime the casing with clean oil before cranking. Change the return filter element and clear the suction strainer, targeting ISO 4406 18/16/13. Keep the case drain unrestricted to tank. Then prove the fan reaches full speed under load and record coolant and hydraulic oil temperature.

주문

Minimum order one piece. Three to six month warranty on new aftermarket units as stated on your proforma invoice. Bench checked and photographed against your order before the wooden case closes, delivery 5 to 8 working days from payment subject to stock. The range sits under 고마쓰 유압 팬 모터.