708-1S-00390 Bomba de ventilador para bulldozer Komatsu D375A-6, bomba hidráulica

Descripción del producto:

Pieza: Bomba hidráulica de ventilador 708-1S-00390 para el tractor de orugas Komatsu D375A-6, listada en datos de piezas comerciales como bomba de ventilador de bulldozer en la familia de bombas 708-1S.

Nota de evidencia: este número no está presente en el catálogo en línea de piezas de Komatsu America que podemos consultar, por lo que el nombre del artículo no pudo confirmarse de primera mano. La aplicación a continuación está establecida comercialmente, no confirmada por el fabricante.

Suministrada como: reemplazo nuevo de marca HTD, fabricado en China. MOQ 1 pieza, caja de madera, despacho de 5 a 8 días hábiles.

Descripción

Not every part number in a supplier catalogue appears in the manufacturer’s own web parts store, and we treat that as a fact to disclose rather than a detail to smooth over. 708-1S-00390 is one of those. Komatsu’s online catalogue returns nothing for it, while several independent trade listings describe the same number as the fan pump for a D375A-6, and the 708-1S prefix is consistent with a fan pump in Komatsu’s numbering.

What we can and cannot state

  • Confirmed by pattern: the 708-1S prefix belongs to Komatsu’s hydraulic pump group, and the sibling numbers in that group are published by Komatsu as Pump Assembly.
  • Trade-established, not manufacturer-confirmed: D375A-6 application.
  • Not verified: displacement, pressure, flow, and any supersession relationship to other 708-1S numbers.

If you need certainty before ordering, the fastest route is a photograph of the plate on your old pump plus the machine serial prefix. We check those against the parts catalogue for your build and tell you if the number is wrong.

Why a D375-class fan pump fails

Large dozers work the hardest cooling duty in earthmoving: continuous high converter load, radiant heat from the engine and torque converter, and a core face that collects fine dust. The fan pump runs near maximum displacement for long periods, in oil that is hotter than the design point, and that combination is what wears the sliding surfaces. Once volumetric efficiency drops, the fan cannot reach speed, oil temperature climbs, and the machine derates.

Test before buying: clean the cores, measure pump output pressure and flow hot, and check the fan motor case drain. Our guía de diagnóstico de bombas de ventilador hidráulicas sets out the sequence, and the check valve article covers the case where every wear part is new and the oil still runs hot.

Montaje

Match shaft spline, pilot, flange, port positions and control orientation against the removed pump. Prime the casing with clean oil before cranking. Change the return filter element and clear the suction strainer, targeting ISO 4406 18/16/13. Keep the case drain unrestricted to tank. Prove full fan speed under load and log temperatures.

Pedido

Pedido mínimo una pieza. Garantía de tres a seis meses en unidades nuevas del mercado de repuestos según lo indicado en su factura proforma. Verificada en banco y fotografiada contra su pedido antes de cerrar la caja de madera, entrega de 5 a 8 días hábiles desde el pago sujeto a existencias. La gama se encuentra bajo Motor de ventilador hidráulico Komatsu.

¿No encuentras una pieza? ¿Necesitas que te la enviemos hoy mismo? Pregúntanos ahora.

Indica tu modelo o número de serie a continuación para recibir un presupuesto definitivo; a menudo, el envío se realiza el mismo día.