15054375 Alloggiamento della trasmissione della pompa PTO per Volvo EC380D EC480D D13F

Descrizione del prodotto:

Parte: 15054375 gruppo presa di forza e alloggiamento della trasmissione della pompa per gli escavatori Volvo EC380D ed EC480D con motore D13F, elencato anche per le versioni EC360 ed EC460, con 17423080 come numero correlato.

Che cos'è: l'interfaccia di trasmissione tra motore e pompe idrauliche. Non è una pompa, non è un motore.

Fornita come: ricambio nuovo di marca HTD, prodotto in Cina. MOQ 1 pezzo, cassa in legno, spedizione in 5-8 giorni lavorativi.

Descrizione

Volvo lists this assembly under several names in the trade: power take-off, PTO group, pump coupling, bearing housing. They all describe the same job, which is to carry engine torque into the hydraulic pump train without letting the pumps run off-centre or lose drive under load. It is a mechanical part, and it is the part that turns a single pump failure into a recurring one.

Applicabilità e prove

Volvo EC380D and EC480D excavators with the D13F engine, with dealer listings extending to EC360 and EC380 builds. 17423080 appears as a related catalogue number in dealer data; we treat that as a supplier cross-reference rather than a confirmed supersession, and quote against your machine’s serial prefix. Volvo’s own online parts catalogue does not return a citable page for 15054375, so the description is dealer-established.

Why this part ruins pumps

  • Worn bearing or bushing. The pump shaft runs slightly off-axis, the couplings wear, and the pump fails early. The new pump does the same thing, and the housing never gets inspected.
  • Worn drive gear or coupling. Torque is not transmitted cleanly, so the pump cannot reach full flow under load. Pressure tests look odd rather than clearly failed.
  • Metal generation. The housing makes its own debris and feeds it directly into the pump inlet, which is how a second pump dies.
  • Perdita esterna at the joint, commonly blamed on the pump shaft seal.

If a machine has lost more than one pump, inspect this assembly before ordering the next pump. Our guida alla diagnosi dei guasti dell'azionamento pompa e della scatola di trasferimento covers the inspection and ispezione dell'ingranaggio di trasmissione shows what wear looks like.

Montaggio

Check gear backlash and bearing play before installation, fill the housing with clean oil, engage the pump splines without forcing them, and confirm the mating surfaces are free of scoring. Flush the circuit and change the filter elements, since the debris that damaged the previous pump is still circulating. Target ISO 4406 18/16/13 or better.

Ordinazione

Send the machine model, engine designation and serial prefix, since this housing differs by engine family. The EC360 and EC460 D12D version is 11128611. Minimum order one piece. Three to six month warranty on new aftermarket units as stated on your proforma invoice; photographed against your order before the wooden case closes, delivery 5 to 8 working days from payment subject to stock. This section covers pump drive housings.

Non riuscite a trovare un pezzo? Vi serve un pezzo spedito oggi? Chiedetecelo ora.

Comunicate il vostro modello o numero di serie qui sotto per ottenere un preventivo sicuro, spesso con spedizione in giornata.